The HP Monitored Power Distribution Unit permits your administrators to monitor current draw at the rack and per PDU. The monitored vertical rack mount power distribution units, provide both single and three-phase monitored power for increased power redundancy, as well as full-rack power utility ranging from 4.9 kVA up to 22 kVA.

In stock
SKU
AF510A

Guarantee safe & secure checkout

Device Type Power distribution strip - rack-mountable
Weight 11.4 kg
Output Voltage AC 200-240 V
Input Connectors 1 x power IEC 60309
Output connectors 36 x power IEC 60320 C13
3 x power IEC 60320 C19
Dimensions (WxDxH) 4.8 cm 152.4 cm
Designed For UPS R/T3000 G2, R1500 G3, R5000, R7000, T750 G2; ProLiant DL120 G6, DL120 G7, DL160 Gen8, DL320e Gen8, DL360 G6, DL360 G7, DL360e Gen8, DL360p Gen8, DL370 G6, DL380 G6, DL380 G7, DL380p Gen8, DL385 G7, DL580 G5, DL785 G6, ML310e Gen8, ML350 G6, ML350e Gen8, ML370 G6, SL230s Gen8, SL270s Gen8; Rack
GENERAL
Device Type Power distribution strip - rack-mountable
COMPATIBILITY INFORMATION
Designed For HP UPS R/T3000 G2 Detachable Cord High Voltage, R12000/3, R1500 G3, R5000, R7000, R8000/3, T1000 G3, T1500 G3, T750 G2
HPE ProLiant DL120 G6, DL120 G6 Base, DL120 G6 Performance, DL120 G7, DL160 Gen8, DL160 Gen8 Entry, DL160 Gen8 Performance, DL320e Gen8, DL320e Gen8 Base, DL320e Gen8 Entry, DL320e Gen8 Performance, DL360 G5, DL360 G6, DL360 G6 Base, DL360 G6 Efficiency, DL360 G6 Entry, DL360 G6 Performance, DL360 G7, DL360 G7 Base, DL360 G7 Entry, DL360 G7 Performance, DL360e Gen8, DL360e Gen8 Entry, DL360e Gen8 Performance, DL360e Gen8 Special Server, DL360p Gen8, DL360p Gen8 Base, DL360p Gen8 CMS, DL360p Gen8 Entry, DL360p Gen8 High Performance, DL365 Base, DL365 Entry, DL365 G5 Base, DL365 G5 Entry, DL365 G5 High Efficiency, DL365 G5 Performance, DL365 Performance, DL370 G6, DL370 G6 Base, DL370 G6 Performance, DL380 G5 Storage Server 2TB SATA Model, DL380 G6, DL380 G6 Base, DL380 G6 Entry, DL380 G6 High Efficiency, DL380 G6 Performance, DL380 G7, DL380 G7 Base, DL380 G7 Entry, DL380 G7 Performance, DL380 G7 Special Server, DL380p Gen8, DL380p Gen8 Base, DL380p Gen8 Entry, DL380p Gen8 High Performance, DL380p Gen8 Special, DL385 G7, DL385 G7 Base, DL385 G7 Entry, DL385 G7 Performance, DL580 G4 High Performance, DL580 G5 Highly Serviceable Tower, DL785 G5, DL785 G6, DL785 G6 Base, DL785 G6 Performance, ML310e Gen8 v2, ML310e Gen8 v2 Base, ML310e Gen8 v2 Enty, ML310e Gen8 v2 Performance, ML350 G5 Base, ML350 G5 Entry, ML350 G6, ML350 G6 Base, ML350 G6 Entry, ML350 G6 Performance, ML350e Gen8, ML350e Gen8 Base, ML350e Gen8 Entry, ML350e Gen8 Performance, ML350e Gen8 v2, ML370 G5, ML370 G5 Base, ML370 G5 Entry, ML370 G5 Performance, ML370 G6, ML370 G6 Base, ML370 G6 Entry, SL230s Gen8 1U Left Half Width Tray, SL230s Gen8 1U Right Half Width Tray, SL230s Gen8 Base 1U Left Tray Server, SL230s Gen8 Base 1U Right Tray Server, SL270s Gen8 1U Left Half Width Tray, SL270s Gen8 1U Right Half Width Tray
HPE Rack
DIMENSIONS & WEIGHT
Width 4.8 cm
Height 152.4 cm
Weight 11.4 kg
POWER DEVICE
Input Voltage Range AC 200 - 240 V
Frequency Provided 50/60 Hz
Frequency Required 50/60 Hz
Input Connectors 1 x power IEC 60309
Power Output Connectors Details 36 x power IEC 60320 C13
3 x power IEC 60320 C19
Output Voltage AC 200-240 V 50/60 Hz
Max Electric Current 32 A
Circuit Protection Circuit breaker
MISCELLANEOUS
Features LED display
Compliant Standards TUV GS, C-Tick, CB
ENVIRONMENTAL PARAMETERS
Min Operating Temperature 10 °C
Max Operating Temperature 50 °C
Humidity Range Operating 10 - 90%
EXPANSION / CONNECTIVITY
Interfaces 2 x management